Communication Tower Equipment Box

Communication Tower Equipment Box

Solution: Thermal insulation rare earth - thermal barrier boating (metal)

Equipment box Surface temperature
Data Comparison
External Surface  Temperature
External surface temperature (applying easyto rare earth coatings) 43.2°C
External surface temperature (without any change) 60.6°C
 
Internal Surface  Temperature
Internal surface temperature (applying easyto rare earth coatings) 33.5°C
Internal surface temperature (without any change) 52.4°C